4.2 R

OLL

S

ENSOR

I

NSTALLATION

Mount the roll sensors to the included roll
sensor brackets using the machine screws
and nylon lock nuts. (Figure 7)

The roll sensors must be mounted

tightly to the brackets.

Figure 7: Mounting the Roll Sensor to the

Roll Sensor Mounting Bracket

When mounting the roll sensors use the
following guidelines and refer to Figure 8.

a) The smaller the distance between A and

B in Figure 8, the better the
performance will be.

Distance A cannot be more than

12”.

b) The roll sensors must not be mounted

below the pivot point.

c) Ensure the roll sensors are sitting

relatively level when the sprayer chassis
and boom are level.

d) Both roll sensors must be mounted with

the circular AMP connector facing
towards the Right-Hand Wing (when
looking from the rear of the sprayer).