beautypg.com

2 valve mounting – NORAC UC4+BC+TA1 User Manual

Page 23

background image

20

4.6.2 Valve Mounting

1. Mount the NORAC valve (V01) on the

sprayer using the valve mounting bracket
(B10).

2. As shown in Figure 24, screw short side of

the threaded rods into the bottom of the
valve block at least 3/8". The valve mounting
holes are drilled and tapped 3/8 NC-1" deep.

3. Tighten the Hex nuts to hold the rods.

4. Put the mounting bracket on the other side

of the tube and tighten with the spring
washers and the Hex nuts. Cut excess off of
the rods, if necessary.

If using bolts, the bolts should thread

into the valve block at least 3/8".
The valve mounting holes are drilled
and tapped 3/8 NC-1" deep. The rule
of thumb for bolt length is 1-1/2"

longer than the tube size.

You must ensure no hydraulic

components will interfere with any

sprayer parts or be pulled tight at
any time.

The recommended location for the

NORAC valve block is on the rear of
the boom center section on the
horizontal cross member, near the
existing valve block.

Figure 24: Valve Mounting Location

NORAC

Valve

Block

Existing

Valve

Block