2 valve mounting – NORAC UC4+BC+SC2 User Manual
Page 21
18
4.6.2 Valve Mounting
1. Mount the NORAC valve (V01) on the
sprayer using the valve mounting bracket
(B10).
2. A good mounting location is on the cross
member, directly above the sprayer valve
block.
3. As shown in Figure 21, screw short side of
the threaded rods into the bottom of the
valve block at least 3/8". The valve mounting
holes are drilled and tapped 3/8 NC-1" deep.
4. Tighten the Hex nuts to hold the rods.
5. Put the mounting bracket on the other side
of the tube and tighten with the spring
washers and the Hex nuts.
6. Cut excess off of the rods, if necessary.
If using bolts, the bolts should thread
into the valve block at least 3/8".
The valve mounting holes are drilled
and tapped 3/8 NC-1" deep. The rule
of thumb for bolt length is 1-1/2"
longer than the tube size.
The recommended location for the
valve is on the rear of the boom main
section on the horizontal cross
member, above the Spra-Coupe
valve block. Orient the valve block
so the NORAC block pressure and
tank lines are on the same side as the
Spra-Coupe pressure and tank lines.
You must ensure no hydraulic
components will interfere with any
sprayer parts or be pulled tight at
any time.
Figure 21: Valve Mounting Location