3 wing sensor installation – NORAC UC4+BC+SC2 User Manual
Page 12
9
4.3 W
ING
S
ENSOR
I
NSTALLATION
1. Assemble the Breakaway Sensor Mounting
Brackets (B11) as show in Figure 4 and
Figure 5.
Figure 4: Breakaway Sensor Bracket
Exploded View
Figure 5: Breakaway Sensor Mounting
Bracket Assembly
To assemble the breakaway sensor bracket:
a) Assemble the bolt and nut into the
collar.
b) Grease the bottom edge of the collar
and the angled tube of the base.
c) Place the collar onto the angled tube of
the mounting base.
d) Install the spring between the collar and
the upper ring of the base.
e) Insert tube through assembly and tighten
the collar
2. Mount the sensor bracket onto the boom.
If possible, mount the sensor
brackets while the booms are in their
folded position to ensure that they
will not interfere with anything when
the boom is folded for transport.
3. The sensor mounting brackets can be
installed with the mounting base behind
(Figure 8) or in front of the tube (Figure
6).
Mounting the sensor bracket to the
break-away section of the boom may
cause the boom to drop suddenly as
a break-away occurs. This will occur
on break-away sections which lift as
they break away.
For optimal boom tip protection, it is
recommended that the sensor be
mounted within approximately two
feet (60cm) of the boom tip.
Please refer to the UC4+ Spray Height
Control system warranty at the end of the
UC4+ Spray Height Control
Operator’s Manual
(M01) for
implications.
4. Mount the NORAC UC4+ ultrasonic sensor
(E02) into the sensor brackets. The sensors
should be oriented forward (ahead) of the
boom (see Figure 6 and Figure 8).
When installing the UC4+ sensors
(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial