beautypg.com

1 boom roll sensor mounting, 2 chassis roll sensor mounting – NORAC UC4+BC+JD7 User Manual

Page 19

background image

17

4.5.1 Boom Roll Sensor Mounting

The boom roll sensor (E04) must be
mounted to the rotating part of the boom.
Follow these guidelines and refer to and
Figure 16 and Figure 17 to mount the
sensor.

a) Make sure you are using the roll sensor

that does NOT have a temperature

probe (only one cable) (E04).

b) The boom roll sensor must be mounted

to the rotating part of the boom
suspension.

c) Use cable-ties to secure the bracket to

a square edge feature (square tube).

d) Ensure the AMP (circular) connector

exits towards the Right Hand Wing
(when looking from the rear of the
sprayer).

e) Securely cable-tie the connector to the

frame.

4.5.2 Chassis Roll Sensor Mounting

The chassis roll sensor must be mounted to
a non-rotating part of the boom. To mount
the chassis roll sensor, follow the following
guidelines and refer to Figure 16 and
Figure 17.

a) Make sure you are mounting the roll

sensor that does have a temperature

probe (2 cables) (E03).

b) Mount the chassis roll sensor (E03) to a

non-rotating part of the boom.

c) Cable-tie the bracket to a square edge

feature (square tube).

d) The AMP (circular) connector MUST

exit towards the Right Hand Wing
(when looking from the rear).

e) Securely cable-tie the connector to the

frame.