beautypg.com

2 valve mounting – NORAC UC4+BC+HD7 User Manual

Page 25

background image

22

Figure 25: Single Acting Valve Block

4.6.2 Valve Mounting

Figure 26: Valve Mounting Location

4. Mount the NORAC valve (V01) on the

sprayer using the valve mounting
bracket (B10).

5. As shown in Figure 26, screw short

side of the threaded rods into the
bottom of the valve block at least 3/8".
The valve mounting holes are drilled and
tapped 3/8 NC-1" deep.

6. Tighten the Hex nuts to hold the rods.

7. Put the mounting bracket on the other

side of the tube and tighten with the
spring washers and the Hex nuts.

8. Cut excess off of the rods, if necessary.

If using bolts, the bolts should

thread into the valve block at
least 3/8". The valve mounting
holes are drilled and tapped 3/8
NC-1" deep. The rule of thumb

for bolt length is 1-1/2" longer
than the tube size.

The recommended mounting

location is on the rear of the
boom main section near the
Hardi valve block.

You must ensure no hydraulic

components will interfere with
any sprayer parts or be pulled
tight at any time.