4.5.2 Chassis Roll Sensor Mounting
1. It is often best to cable tie the chassis

roll sensor in place. When mounting

the chassis roll sensor follow the
guidelines and refer to Figure 18.

The chassis roll sensor must be

mounted on a portion of the
sprayer that does not pivot and is
as close to the boom frame roll
sensor as possible (Figure 16).

a) Make sure you are using the roll

sensor with the temperature probe
(E03).

b) Ensure the roll sensor is level with

respect to the chassis.

c) The AMP (circular) connector

MUST exit towards the right
hand wing
.

d) Make sure the temperature probe is

able to reach the side of the valve
block.

Figure 18: Chassis Roll Sensor

Mounting

2. Fasten the temperature probe to the

UC4+ valve block, using the supplied
3/8”x1/2” bolt as shown in Figure 19.

3. Cable-tie the temperature probe cable

and AMP (circular) connector securely
to a frame member.