beautypg.com

NORAC UC4+BC+CS3 User Manual

Page 13

background image

10

Rainflaps are only installed in the

wing sensor brackets and are not
installed for 120’ booms.

4. Insert one side of the rainflap rod into

the pre-bent hinge tab on the sensor
bracket. (Figure 6)

Figure 6: Rainflap Rod in Pre-Bent

Hinge Tab

5. Align the other side of the rainflap rod

with the unbent hinge tab. (Figure 7)

Figure 7: Align Rainflap Rod

6. Bend the hinge tab inward over the

rainflap rod until the hinge tab fits
securely in the detent groove on the
backside of the sensor bracket. (Figure
8
)

Figure 8: Bend Rainflap Hinge Tab

7. Ensure the rainflap actuates smoothly

when the bracket is turned upside down
and returns to the open position when
the sensor bracket is returned to its
operating position (sensor pointing
downwards toward the ground).


General Mounting Rules for Low

Profile Brackets:
A. Minimize the distance between the bolts

to prevent bending the bracket and
prevent the bracket from loosening
over time.

B. Ensure the bracket is mounted tight

against the bottom of the boom,
minimizing the distance between the
boom structure and the angled flange.

Figure 9: Bracket Mounting Guidelines