beautypg.com

7 electrical installation, 1 4000 series installation, 7electrical installation – NORAC UC4.5-BC-NT4 User Manual

Page 20

background image



17

7

Electrical Installation

1. Install the UC4.5 Control Panel (E01) in the cab of the sprayer. Mount the panel where it

will be clearly visible and within easy reach of the operator.

A good spot to mount the UC4.5 control panel is on the right hand side of the cab to the
Roll Over Protection Bar. Four pilot holes for the screws provided need to be drilled to
facilitate the control panel mounting.
Another option is to purchase an adapter for the flexible panel mount that has a 3/8" NC
threaded stud on the end to bolt through an existing mount. These can be found at your
local outdoor store as a RAM mount part number RAM-B-236. (See

http://www.ram-

mount.com/

)

2. Connect the UC4.5 power cable (C10) to the 16-pin and 4-pin connectors on the back of

the UC4.5 Control Panel in the cab. Cable tie C10 to the RAM mount to help provide
strain relief.

Ensure the UC4.5 Control Panel’s power is OFF for the remaining installation.

(Bottom of switch pressed IN).

7.1

4000 Series Installation

1. Connect C30 to P6A on C10 using the 2-way coupler (E12). Connect the 3-pin connector

on C30 to the power bar in the cab.

2. Route the free ends of C10 along the side of the cab post and under the floor mat.

Figure 18: Cable Configurations: C10, C14 and C30