Figure 18: Hole under Floor Mat

Figure 19: Alternate Cab Exit for Cabling

The hole in the floor may be too small for the connector. In this situation the

cable can be routed out the back of the cab through an opening close to the

bottom of the rear, right window (Figure 19).

5. Connect P12/P6 on C10 to R12/R6 of C11.

6. Route C11 to the rear of the sprayer near the sprayer valve block. Run the cables along

the sprayer frame with the JD harness.

Figure 20: Cable Configurations: C03 and C13

7. Connect S3 on cable C13 to the 3-pin tower (T3) on C11.

8. Route the free end of C13 under the sprayer to the shuttle valve manifold. Unplug the load

sense jam valve connector (Figure 21). Plug the connectors on C13 into the load sense
jam valve connectors.

Cab Exit