Quick start – Mytek Digital Protools HD DIO Card (ver. 1.1 / Oct 2010) User Manual
Page 5

Mytek Protools-HD DIO Card – User Manual
Quick Start
1. DIO-HD card installation
Remove the top cover from the converter, unscrew 
DIOCARD1 slot plate (first slot from the right while looking 
at the rear panel) and install the DIO-HD card using 
provided screws. Double check that all the connector pins 
match properly with the pins of the connector on the main 
converter board. 
2. Connecting the card to Protools HD ® system
The Pro Tools card must be connected to the Primary Port of 
the DIO-HD card. A maximum of two converters (which can 
be of different brands) can be connected to each Protools 
card. In the case of more than one converter, the second one 
should be daisy chained from the Expansion Port of the first 
converter to the Primary Port of the second. 
3. Connecting the clock signal
The first converter in the Pro Tools system must operate on 
internal clock and is the system clock master. We 
recommend always making Mytek the master as it 
incorporates a superior clock generator with multiple 
wordclock outputs. When a 192 I/O Digidesign interface is 
connected in the slave configuration, WCK on the front 
panel of Mytek converter must be set to FS/4.
4.
Hardware Setup Configuration
Choose Setup > Hardware Setup and check sampling
frequency, clock signal (should be set to Internal) and 
confirm Input and Output interfaces are present. Every 
converter in the menu should be Set to Default
Remember to turn off 
power, and disconnect 
power and signal cables 
while working with the top 
cover removed.
Turn down the amplifier 
and speakers connected to 
the computer while 
launching the Pro Tools 
application.
User Manual ver. 1.1 / oct 2010 www.mytekdigital.com
Page: 5 / 29