M1x22_dial_aborted, M1x22_sync_recovered, M1x22_gpio_interrupt – Maxim Integrated 73M1822/73M1922 Control Module User Manual
Page 20: Section 6

73M1822/73M1922 Control Module User Guide
UG_1x22_053
20
Rev. 1.0
5.2.13 M1X22_DIAL_ABORTED
This event is generated when a pulse dial session is aborted or canceled by the user application.
Parameters
Data Type
Name
Description
unsigned int
event_id
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
5.2.14 M1X22_SYNC_RECOVERED
This event is generated after a successful recovery from the barrier sync failure.
Parameters
Data Type
Name
Description
unsigned int
event_id
M1X22_SYNC_RECOVERED
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
5.2.15 M1X22_GPIO_INTERRUPT
This event occurs when an input GPIO interrupt is triggered. The “data1” field contains the source GPIO
that generates the interrupt.
Parameters
Data Type
Name
Description
unsigned int
event_id
M1X22_GPIO_INTERRUPT
.
unsigned int
channel_cid
Channel CID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
The GPIO that triggers the interrupt event.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.