5.2.7 M1X22_RING_DETECT_END
This event is generated when the driver detects the end of the ring burst.
Parameters
Data Type
Name
Description
unsigned int
event_id
M1X22_RING_DETECT_END
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
Ring burst frequency (in Hz)
unsigned int
event_data2
Ring burst duration (in ms)
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
5.2.8 M1X22_SYNC_LOSS_DETECT
This event is generated when the driver detects the failure of synchronization across the barrier path.
Parameters
Data Type
Name
Description
unsigned int
event_id
M1X22_SYNC_LOSS_DETECT
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
5.2.9 M1X22_OV_DETECT
This event is generated on detection of an over voltage line condition.
Parameters
Data Type
Name
Description
unsigned int
event_id
M1X22_OV_DETECT
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4