beautypg.com

Family d commands—verify fixed length – Maxim Integrated MAXQ20-Based Microcontroller Bootloader Command Reference User Manual

Page 15

background image

MAXQ20-Based Microcontroller Bootloader Command Reference

15

Family D Commands—Verify Fixed Length

Command D0h—Load/Verify Code Fixed Length

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6-21

Byte22

Byte23

Byte24

Input

D0h

10h

AddrL

AddrH

Data1

xx

Data16

00h

00h

Output

3Eh


This command combines the functionality of the "Load Code Fixed Length" and "Verify Code Fixed Length"
commands


Command D1h—Load/Verify Data Fixed Length

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

Byte9

Byte10

Input

D1h

04h

AddrL

AddrH

Data1

Data2

Data3

Data4

00h

00h

Output

3Eh


This command is only useful in devices with nonvolatile data memory. This command combines the functionality
of the "Load Data Fixed Length" and "Verify Data Fixed Length" commands.