PHONOGENE Panel Controls (cont’d)
22. SLIDE Bipolar Panel Control: manual bipolar panel control for scanning the pieces
of sound that result from setting Gene-Size to greater than 10%. Moves/ slides
through the Genes (aka grains). Allows for scrubbing of the recorded material
and is always dependent upon the GENE-SIZE setting.
23. SLIDE CV IN: bipolar control input for SLIDE. Range +/-4V.
24. SLIDE CV IN Attenuvertor: bipolar attenuator for SLIDE.
25. GENE-SIZE CV IN: unipolar control input setting size divisor of audio buffer, dividing
with respect to the buffer size as set by Record or Splice length. This
parameter “auto-splices” the recorded material like a machine, with no regard
to source material. Operates with great precision and the ability to cut pieces
so small that the original source material is completely unintelligible.
Nondestructive. At 0V there is no effect. Range 0V to +8V.
26. GENE-SIZE CV IN Attenuator: unipolar attenuator for GENE-SIZE.
27. GENE-SHIFT: clock signal at this input advances Phonogene to next Gene, in
chronological order. Always dependent upon the GENE-SIZE setting. Needs
at least 1.5V trigger signal to operate.
28. GENE-SIZE Panel Control: manual unipolar control which sets Gene-Size divisor.