CRITERIA FOR CALIBRATING AUTO LEVLEING SYSTEM

There are two main reasons for needing to calibrate the Automatic Leveling System.
1. Battery is completely drained and completely discharged.
2. Battery has been disconnected.

Any event that results in total loss of power to the Control Panel will result in the need to calibrate the
Auto Leveling System.

CALIBRATING AUTO LEVELING SYSTEM INSTRUCTIONS

1. Manually level coach utilizing a bubble-type level. A 48” level is recommended and should be
placed on the floor in the kitchen area. See Page 13 in the Electronic Controlled Hydraulic
Leveling System.
2. Unscrew mounting screws holding the Leveling Control Panel in the dash and gently pull Control
Panel out of the dash.

CAUTION - Be careful not to unplug wire harnesses.

3. Locate small YELLOW button on back of Control Panel (Fig. 3A).
4. Push and hold YELLOW button for 15 seconds.
5. Release button for 3 seconds.
6. Press button again and release immediately.
7. Auto Leveling System is now calibrated, return Control Panel to dash and remount screws to
secure Control Panel in dash.
8. Push the ALL RETRACT button to retract all jacks.
9. Push AUTO LEVEL button to put system into Automatic Leveling Mode to test that calibration of
system is complete.