5.5. WATER
OUTLET
CONNECTION
The machine is equipped with drainage pipe.
The internal diameter of the pipe is ½ inch therefore it can be attached to any standard ½” rubber holder
General rules for installing outlet
A siphon drain is recommended. When installing it is necessary to follow the following advice:
• As the outlet water is at 95°C, the end of the out let pipe must be fixed to the rubber holder, using the clips
provided.
• The outlet pipe must not have any sharp bends and consequent narrowing.
• The end of the outlet pipe must be at a height comprised between 400 mm and 800 mm, compared to the
surface the appliance stands on.
• The end of the pope must not be immerged in water.
• The internal diameter of the outlet pipe must be at least 40 mm.
• If possible, install a 50 mm diameter outlet pipe.
• The outlet pipe provided with the appliance must not be extended. Any extensions may cause flow-back
problems into the vat.
fig. 6 - Outlet pipe connection. The height of the outlet hole "A", compared to the surface on which the appliance stands, must be:
Min 400 - Max 800
mm.
IMPORTANT
The outlet must comply with international legislation. Our company will accept no
liability for pollution caused by improper use of the machine.
Fig. 7 – adaptor with rubber holder for ½” pipe.