Model 380, Tedea-huntleigh, Co-planar beam load cell – KERN & SOHN MXS 300K100M Addendum User Manual
Page 2: Specifications

www.vpgtransducers.com
2
Model 380
Technical contact in Americas: [email protected];
Europe: [email protected]; Asia: [email protected]
Document No.: 12075
Revision: 26-Jul-2012
Co-Planar Beam Load Cell
SPECIFICATIONS
PARAMETER
VALUE
UNIT
Rated capacity—R.C. (E
max
)
7.5, 37.5, 50, 75, 150, 250
kg
TH accuracy class
E
G4
H5
OIML Accuracy class
NA
C3
C4
Maximum no. of intervals (n)
NA
3000
4000
Y = E
max
/V
min
*
NA
7500*
7500*
Rated output—R.O.
1.0
mV/V
Rated output tolerance
0.10
0.001
±mV/V
Zero balance
0.10
±mV/V
Creep, 30 min.
0.074
0.024
0.018
±% of load
Zero return, 30 min.
0.05
0.0167
0.0125
±% of load
Temperature effect on output
0.002
0.001
0.00075
±% of load/°C
Temperature effect on zero
0.007
0.00186
0.00186
±% of R.O./°C
Input impedance
1160±15
Ω
Output impedance
1000±10
Ω
Insulation resistance
5000
MΩ
Temperature range, compensated
–10 to +40
°C
Temperature range, safe
–30 to +70
°C
Maximum safe central overload
300
% of R.C.
Ultimate static overload
400
% of R.C.
Safe side load
200
% of R.C.
Cable type
4 conductors, 26AWG, flat, PVC
Cable length
1.5
m
Color code
+Exc: Green, +Sig: Red, -Exc: blk, -Sig: wht
Construction
Aluminum, RTV potting
Environmental protection
IP65
Outline dimensions drawing
378.000.003
* Consult factory for higher Y values availability
All specifications subject to change without notice.
Wiring Schematic Diagram
+ve Input (Green)
–ve Input (Black)
+ve Output (Red)
–ve Output (White)
The load cell is provided with a 4 conductor ribbon
cable and with optional AMP#103957-4 connector
4
1
2
5