8.1 Operation limits
• The weighing bridges are designed extremely robust. However the load limits
according to the following table should not be exceeded!
• Depending on the type of load receptacle, the static carrying capacity, i.e. the
maximum admissible load is:
Weighing
ranges
600kg
1500kg
With centrical load
3000kg 4500kg
With side stress
2000kg
3000kg
With one-sided loading
1000kg
1500kg
With single-wheel load
400kg
800kg
8.2 Operation with access ramps
• The load plate of the weighing bridge is an active weighing element, the access
ramps are passive, i.e. during the weighing process all wheels of the conveying
vehicles must rest on the load plate.
8.3 Load/unload weighing bridge
• Place the load on the scales using a lifting truck, a crane or a forklift truck. Ensure
that the load is not swinging when it is placed onto the scales.
• Lift the load first vertically at least 10 cm above the scales before it is removed or
newly placed.
11
KFD
V20-IA-e-1110