Animal
weighing
function
0.0
g
Vn T
ANL
The animal weighing function can be applied for busy weighing.
During a defined period the average value of the weighing results is
formed.
The more unquiet the weighed item, the longer the period should
be selected.
Ö
In weighing mode keep the PRINT key pressed until [Unit]
appears.
Ö
Press the MODE button several times until „ANL“ is displayed.
Ö
Acknowledge using SET key, the current setting is displayed.
Ö
Select the desired settings by pressing the MODE key
ANL
3
Period 3 seconds
ANL
5
Period 5 seconds
ANL
10 Period 10 seconds
ANL
15 Period 15 seconds
ANL
off Animal weighing not active
Ö
Use the SET key to confirm selection.
Ö
Put the weighing good (animal) on the weighing plate and press
the SET button. In the display runs a „Countdown“.
The average value of the weighing results is displayed and
remains displayed on the screen.
Ö
Use the SET key to change between animal weighing and
normal weighing.
Ö
Press the SET key to restart the weighing cycle for animal
weighing.