0 board installation, 0 contact keri systems, Sb-593 satellite board – Keri Systems SB-593 User Manual
Page 4: Quick start guide
![background image](/manuals/697191/4/background.png)
SB-593 Satellite Board
Quick Start Guide
Page 4 of 4
P/N: 01925-001 Rev. B
5.0
Board Installation
Perform the following steps to install an SB-593 Satellite Board on a PXL-250, PXL-500/PXL-510, or PXL-500G-1
controller. The SB-593 Satellite Board comes with two sizes of stand-offs. Due to changes made to the relays, some PXL
controllers will require the use of taller stand-offs.
•
The smaller stand-offs are to be uses with PXL-500 controllers.
•
The taller stand-offs are to be used when the Satellite Board is connecting to the new PXL-500-1 or PXL-500G-1
controllers.
Installation of these stand-offs are done exactly as before.
1.
Turn the controller's power OFF.
2.
Line up the upper left-hand corner of the Satellite PCB with the controller PCB.
3.
Line up the stand-offs in the top two corners of the Satellite PCB with corresponding mounting holes in the controller
PCB.
4.
Align the Satellite Board’s connector pins to the PXL mounting holes.
NOTE: If you are installing the SB-593 (which has two rows of connector pins) on a PXL-250 controller (which has one
row of mounting holes) it does not matter which row of connector pins are inserted in the mounting holes.
5.
Gently press the two boards together with each stand-off into its mounting hole and with the connector pins meshing
together with their mounting holes.
6.
Turn the controller’s power ON.
7.
If the P2 mounting holes have the PXL J2 connector pins inserted correctly, the Power LED6 will illuminated and
remain so as long as the connection continues and power is supplied to the unit.
8.
If the P3 mounting holes have the PXL J3 connector pins inserted correctly, the SDA LED5 will flicker and continue
to do so as long as the connection continues and power is supplied to the unit.
6.0
Contact Keri Systems
End of document.
Keri USA
Keri UK, Ireland, Europe
2305 Bering Drive
San Jose, CA 95131
Unit 17
Park Farm Industrial Estate
Ermine Street
Buntingford
Herts SG9 9AZ UK
Telephone: (800) 260-5265
(408) 435-8400
Telephone: + 44 (0) 1763 273 243
Fax: (408) 577-1792
Fax:+ 44 (0) 1763 274 106
Web: www.kerisys.com
Web:www.kerisystems.co.uk