Editing the pro solo – Kenton Pro-Solo mk1 User Manual
Page 3

Switching On
When the PRO SOLO is switched on, the words KENTON PRO SOLO scroll across the display.
The Display
There are 3 digits on the 7-segment display. The 1st digit shows which parameter is ready
for editing. The right-hand, 2nd & 3rd digits will then display what the value of the
parameter is.
There are also 3 red dots which you may see appear. The 1st dot when lit indicates the
SELECT button is in reverse operation (see below), the middle dot when lit indicates the
current value displayed is a negative number, and the 3rd dot will light when ever the
PRO SOLO`s gate is on (key pressed down);
Stepping Through Parameters
Each parameter is accessed using the SELECT button. There are 20 parameters in the
menu, listed in the next section `Parameters`.
Press the SELECT button to get to the parameter in question, then use the INCrement (+)
and DECrement (-) buttons to edit the value.
If you press and hold the SELECT button for more than 1 second, you can step through the
parameters in the opposite direction. A red LED dot will light up to indicate this. If the
SELECT button is pressed and held for 1 second again, the direction will return to normal
and the red LED dot will disappear.
Displaying values above 99
When displaying values from 0 to 99, you will see the digits as you would expect.
When displaying values above 99, the following format is used :-
a dash " - " at the bottom of the left-hand display = 100+
a dash " - " in the middle of the left-hand display = 110+
a dash " - " at the top of the left-hand display = 120+
No values above 127 are used.
Speeding up editing
If you press and hold the INC key, then also hold the DEC key, the value will increase
faster. If you press and hold the DEC key then also hold the INC key, the value will
decrease faster.
Storing Set-ups
The set-ups can be stored in non-volatile memory. To do this, press & hold the SELECT
button (for approx. 6 seconds) till the display reads `st` (store).
EDITING THE PRO SOLO
Gate on
SELECT steps
backwards
negative
value