TROUBLESHOOTING GUIDE (continued)

1. Filter pump not attached to
system and/or switch on.

2. Circulation line is blocked.

3. Incorrect inlet and outlet hose
direction.

4. Scale on the flow sensor.

5. Flow sensor cord is loose.

6. Inner timer conflict between filter pump
and Ozone & saltwater system.

7. Flow sensor failure.

1. Dirt or scale on titanium plates.

2. Low salt level / No salt.

3. Electrolytic cell cord is loose.

4. Possible electrolytic cell failure.

1. High salt level.

1. Display and all lights are off - the
system does not power up.

1. Ozone generator assembly
failure.

Ensure filter pump is attached and operating.
See "Setup Instruction".

If your unit has plunger valves, ensure that
they are open.
Clear your filter cartridge and cell from debris
and dirt. See “Maintenance”.
Release all trapped air in the circulation line.
See the filter pump manual.

Check the direction of the inlet and the outlet

hose. Reverse the hoses if necessary. See “Set
Up

Instructions”.

Clean the flow sensor, paying special attention
to the hinge. See “Maintenance”.

Plug the flow sensor firmly into the flow
sensor

receptacle.

Reset both timers on the filter pump and
Ozone & Saltwater System.

Contact Intex Service Center.

Remove the electrolytic cell for inspection.
Clean it if necessary. See “Maintenance”.

Add salt. See “Salt & Pool Water Volumes”.

Ensure that the cell cord is plugged firmly into
the cell housing receptacle.

Contact Intex Service Center. Replace the cell
if

needed.

Partially drain the pool and refill it with fresh
water. See “Salt & Pool Water Volumes”.

Household voltage is too high or too low
(+ 20%). Check the voltage is within the
range stated on the device housing.
Contact Intex Service Center.

Contact Intex Service Center. Replace
the assembly following the relevant
instruction in maintenance section.