beautypg.com

3 nnecting an epim-100fx or epim-100fmb, Nnecting an epim-100fx or epim-100fmb -4, Section 5.1.3 – Cabletron Systems SEH100TX-22 User Manual

Page 38

background image

Chapter 5: Connecting to the Network

5-4

SEH100TX User’s Guide

c.

Check the cable for continuity.

d. Check that the twisted pair connection meets the cable

specifications outlined in Section 3.1.2.

e.

Check that the crossover switch is in the correct position.

If a link is not established, contact Cabletron Systems Technical Support.

5.1.3

nnecting an EPIM-100FX or EPIM-100FMB

The EPIM-100FX and EPIM-100FMB have an SC style network port
(see Figure 5-3). Cabletron Systems supplies fiber optic cables that use
SC connectors that are keyed to insure proper crossover of the transmit
and receive fibers.

Use the following steps to connect a fiber segment to the EPIM-100FX or
EPIM-100FMB:

1. Remove the protective plastic covers from the fiber optic ports on the

module port and from the ends of the connectors.

2. Insert one end of the SC connector into the SEH EPIM-100FX or

EPIM-100FMB. See Figure 5-3.

3. At the other end of the fiber optic cable, attach the SC connector to the

other device.

NOTE

An odd number of crossovers (preferably one) must be
maintained between devices so that the transmit port of one
device is connected to the receive port of the other device and
vice versa.

!

CAUTION

Do not touch the ends of the fiber optic strands, and do not let
the ends come in contact with dust, dirt, or other contaminants.
Contamination of the ends causes problems in data
transmissions. If the ends become contaminated, clean them
with alcohol using a soft, clean, lint-free cloth.