beautypg.com

4 operating specifications, 1 power supply requirements, 2 environmental requirements – Cabletron Systems SEH100TX-22 User Manual

Page 22: 5 agency approvals, 1 safety, 2 emission, Operating specifications -6 3.4.1, Power supply requirements -6, Environmental requirements -6, Agency approvals -6 3.5.1

background image

Chapter 3: Installation Requirements and Specifications

3-6

SEH100TX User’s Guide

3.4

OPERATING SPECIFICATIONS

This section details power supply and environmental requirements.

3.4.1

Power Supply Requirements

The SEH has a universal power supply. The input power requirements are
listed in Table 3-2.

3.4.2

Environmental Requirements

The environmental requirements for the SEH are detailed in this section.

Operating Temperature:

5

°

C to 40

°

C

(41

°

F to 104

°

F)

Storage Temperature:

-30

°

C to 73

°

C (-22

°

F to 164

°

F)

Operating Humidity:

15% to 95% (non-condensing)

3.5

AGENCY APPROVALS

The safety, emission, and immunity approvals for the SEH are detailed in
this section.

3.5.1

Safety

This unit meets the requirements of UL 1950, CSA C22.2 No. 950, IEC
950, and EN 60950.

3.5.2

Emission

This unit is compliant with the requirements of FCC Part 15 Class A,
EN 55022 Class A, and VCCI Class I.

Table 3-2

Power Requirements

Line Input Range

Current

Frequency

100–125 Vac

4.0 A

50/60 Hz

200–250 Vac

2.0 A