Chapter 4: Installation

4-2

SEH100TX User’s Guide

The SEH may be installed on a tabletop or shelf, or in a 19-inch rack, and
configured as a standalone or stacked hub.

Go to Section 4.2 to install an SEH on a table or shelf. Go to Section 4.3
to install the SEH in a rack.

4.2

TABLETOP OR SHELF INSTALLATION

This section provides guidelines for installation on a tabletop or shelf.

Tabletop and shelf installations must be within reach of the network
cabling and meet the requirements listed below:

In a shelf installation, the shelf must be able to support 30 pounds of
static weight for each device in the stack.

Maintain a temperature of between 5

°

C (41

°

F) and 40

°

C (104

°

F) at

the installation site with fluctuations of less than 10

°

C per hour.

The SEH must be located within seven feet of its power source and with
an unrestricted free surface area as shown in Figure 4-1.

Figure 4-1

Tabletop or Shelf Installation

Proceed to Section 4.4, Powering Up and Stacking the SEH.

!

CAUTION

In order to allow for proper cooling, there must be a two-inch
clearance on either side and the back of the unit.

C

A

B

1510_13

A = 15.24 cm (6 in)
B = 45.72 cm (18 in)
C = 53.34 cm (21 in)
D = 213.36 cm (7 ft)