Installing a cover tamper switch, To install the tamper reed switch (figure 9), Figure 9. installing the reed switch – Interlogix SuperBus 2000 8Z User Manual
Page 5: Setting the module unit numbers
5
Installing a Cover Tamper Switch
Installing a Cover Tamper Switch
If you are mounting the module in its own plastic and not
mounting it inside a cabinet, you need to add cover tamper
detection.
To do this, install a UL listed 1/4-inch press-fit reed switch
on the module back-plate and wire the switch to one of the
module zone input terminals or unused panel zone input ter-
minals. Once programmed, if someone opens the module
cover, the tamper switch opens and causes an alarm.
The reed switch holder and magnet clip are located at the
bottom of the back-plate (see Figure 3 for details).
To install the tamper reed switch (Figure 9):
1.
Slide the reed switch into the reed switch holder
located on the module back-plate shown in Figure 9.
2.
Insert the magnet into the nibs on the module cover.
Remove the magnet clip from the module back-plate
and press the magnet clip down over the magnet until it
clicks into place (Figure 9).
3.
Connect the normally closed reed switch (in series with
a 2.0K ohm EOL resistor) to the module ZONE 1 (1)
and ZONE COMMON (2) terminals as shown in Fig-
ure 8. The resistor should be located at the reed switch
inside the module housing.
Figure 9.
Installing the Reed Switch
Setting the Module Unit Numbers
On Concord (software versions 1.0–1.6) and
UltraGard Panels
Locate the DIP switches on the module circuit board (Fig-
ure 1) and set switch 1 to “M” (on - for manual) (Figure 10).
Set the remaining switches for the desired unit number.
ÁIG"42
Do not change DIP switch settings once the panel is
powered up.
- UNIT NUMBER 0–7 for UltraGard
- UNIT NUMBER 0–15 for Concord
Figure 10. Module Unit Number DIP Switch Settings
(Non-SuperBus 2000 panels)
On Concord (software versions 2.0 or later) and
Advent Panels
Locate the DIP switches on the module circuit board (Fig-
ure 1) and set all switches to “A” (off - for automatic). The
unit number will be automatically set when powering up the
system.
9712G12A.DSF
MODULE
BACK-PLATE
MODULE
COVER
REED
SWITCH
MAGNET
CLIP
MAGNET
TO ANY ZONE
INPUT
2.0K OHM EOL
RESISTOR (49-467)
9712G09A.DSF
UNIT NUMBER 0
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 1
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 2
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 3
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 4
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 5
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 6
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 7
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 8
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 9
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 10
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 11
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 12
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 13
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 14
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
UNIT NUMBER 15--Do not use in Concord RF systems.
M
A
M
A
M
A
M
A
M
A
M
A
M
A
M
A
M
A
M
A
M
A
M
A
M
A
M
A
M
A
M
A