Wiring the Module
Wiring the Module
To Wire the Module to a Panel
«ÀÌ>Ìt
On Advent panels, the BUS 1 and BUS 2 headers
must be used only for fire or burglary applications. Do
not mix fire and burglary bus devices on either header.
1.
Make sure the panel AC power is turned off or
removed, and the panel backup battery(s) are
disconnected.
2.
Wire the module to the panel as shown in Figure 7 and
explained in Table 4.
Figure 7.
General Module Wiring
* Panel SuperBus device connector wiring harness.
(Connect to either panel connector.)
To Wire Detectors to the Module
Follow the maximum zone input wire length (run)
guidelines in Table 5 based on the type of wire used.
«ÀÌ>Ìt
For Advent UL-864 Listed Installations, all inputs must
be dedicated to either fire or burglary applications. Do
not mix fire and burglary on
any module in any
partition for these installations.
1.
Figure 8 shows an example of how to connect up to
eight normally closed (N/C) or normally open (N/O)
intrusion circuits to the module.
Figure 8.
Connecting N/C and N/O Intrusion Circuits
to the Module
Table 4. SuperBus Module/Panel Wiring
Module
Terminals
Advent*
Ultra-
Gard
Concord
13
(+12VDC)
Red
12 4
14 (BUS A)
Green
13
5
15 (BUS B)
White
14
6
16 (GND)
Black
15
3
9712G03A.DSF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ZONE COM
M
ON
ZO
NE 1
ZO
NE 2
+12
VDC (
R
ED)
BUS A (
G
RN)
BUS B (
W
HT)
GND (
B
L
K
)
TO PANEL
SUPERBUS TERMINALS
OR CONNECTOR
(SEE TABLE)
TO ZONE
INPUT
DEVICE
(SHARED COMMONS)
ZO
NE 3
ZO
NE 4
ZO
NE 5
ZONE COM
M
ON
ZONE COM
M
ON
ZO
NE 6
ZO
NE 7
ZONE COM
M
ON
ZO
NE 8
Table 5. Zone Input Wire Runs
Gauge
Max. Wire Run*
18
750 Feet
22
300 Feet
*Wire run based on 10 ohms maximum wire and
device resistance including 2.0K ohm EOL resistor.
9712G04A.DSF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ZO
NE 1
ZONE COM
UL-LISTED
NORMALLY
OPEN
(N/O)
CONTACTS
IN PARALLEL
2.0K OHM EOL RESISTOR 49-467
(INSTALL AT LAST DEVICE)
UL-LISTED
NORMALLY
CLOSED
(N/C)
CONTACTS
IN SERIES
< OR >