NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
Segments 5 to 8 are reserved for future use. Table 13
describes the segment options:
Table 13: Location 7 options
Segment
Description
1
Alarm restores
2
Telephone fault
3
Start download
4
Failure to communicate, data lost
5 to 8
Reserved for future use
Location 8, events to report to central
station
– phone line is good
Note:
Reporting must be enabled in the control panel for this
location to function.
This location has 16 segments and selects the partitions to
include when reporting to the central station. To exclude any
partition from reporting, turn off the LED corresponding to that
particular partition number. Enter the numbers of the partitions
to include for each type of report found in segments 1 through
16. Factory default is all partitions off for all segments. Table
14 describes the segment options:
Table 14: Location 8 options
Segment
Description
1
Alarms
2
Open/Close
3
Bypass
4
Zone Trouble
5
Power Trouble (AC failure or low battery)
6
Siren and telephone fault
7
Test reports
8
Program, download and log full
9
Tampers
10
Short circuit and ground fault
11
Sensor lost
12
Sensor low battery
13
Expander trouble
14
Failure to communicate
15
Zone activity monitor
16
Reserved for future use
Location 9, special events to report to
central station
– phone line is good
This location has 8 segments and selects the partitions to
include when reporting special events to the central station. To
exclude any partition from reporting, simply turn off the LED
corresponding to that particular partition number. Enter the
numbers of the partitions to include for each type of report
found in segments 1 through 4. Factory default is all partitions
off for all segments. Segments 5 to 8 are reserved for future
use. Table 15 describes the segment options:
Table 15: Location 9 options
Segment
Description
1
Alarm restores
2
Telephone fault
3
Start download
4
Failure to communicate, data lost
5 to 8
Reserved for future use
Location 10, events to report to email
–
phone line is good
Note:
Reporting must be enabled in the control panel for this
location to function.
This location has 16 segments and selects the partitions to
include when reporting to email. To exclude any partition from
reporting, turn off the LED corresponding to that particular
partition number. Enter the numbers of the partitions to include
for each type of report found in segments 1 through 16.
Factory default is all partitions off for all segments. Table 16
describes the segment options:
Table 16: Location 10 options
Segment
Description
1
Alarms
2
Open/Close
3
Bypass
4
Zone Trouble
5
Power Trouble (AC failure or low battery)
6
Siren and telephone fault
7
Test reports
8
Program, download and log full
9
Tampers
10
Short circuit and ground fault