NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
This location has 16 segments and selects the partitions to
include when reporting to email. To exclude any partition from
reporting, turn off the LED corresponding to that particular
partition number. Enter the numbers of the partitions to include
for each type of report found in segments 1 through 16.
Factory default is all partitions off for all segments. Table 10
describes the segment options:
Table 10: Location 4 options
Segment
Description
1
Alarms
2
Open/Close
3
Bypass
4
Zone Trouble
5
Power Trouble (AC failure or low battery)
6
Siren and telephone fault
7
Test reports
8
Program, download and log full
9
Tampers
10
Short circuit and ground fault
11
Sensor lost
12
Sensor low battery
13
Expander trouble
14
Failure to communicate
15
Zone activity monitor
16
Reserved for future use
Location 5, special events to report to email
– phone fault detected
This location has 8 segments and selects the partitions to
include when reporting special events to email. To exclude any
partition from reporting, turn off the LED corresponding to that
particular partition number. Enter the numbers of the partitions
to include for each type of report found in segments 1 through
4. Factory default is all partitions off for all segments.
Segments 5 to 8 are reserved for future use. Table 11
describes the segment options:
Table 11: Location 5 options
Segment
Description
1
Alarm restores
2
Telephone fault
3
Start download
4
Failure to communicate, data lost
Segment
Description
5 to 8
Reserved for future use
Location 6, events to report to pager
–
phone fault detected
Note:
Reporting must be enabled in the control panel for this
location to function.
This location has 16 segments and selects the partitions to
include when reporting to a pager. To exclude any partition
from reporting, turn off the LED corresponding to that particular
partition number. Enter the numbers of the partitions to include
for each type of report found in segments 1 through 16.
Factory default is all partitions off for all segments. Table 12
describes the segment options:
Table 12: Location 6 options
Segment
Description
1
Alarms
2
Open/Close
3
Bypass
4
Zone Trouble
5
Power Trouble (AC failure or low battery)
6
Siren and telephone fault
7
Test reports
8
Program, download and log full
9
Tampers
10
Short circuit and ground fault
11
Sensor lost
12
Sensor low battery
13
Expander trouble
14
Failure to communicate
15
Zone activity monitor
16
Reserved for future use
Location 7, special events to report to
pager
– phone fault detected
This location has 8 segments and selects the partitions to
include when reporting special events to a pager. To exclude
any partition from reporting, turn off the LED corresponding to
that particular partition number. Enter the numbers of the
partitions to include for each type of report found in segments 1
through 4. Factory default is all partitions off for all segments.