NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet

This location has 16 segments and selects the partitions to

include when reporting to email. To exclude any partition from

reporting, turn off the LED corresponding to that particular

partition number. Enter the numbers of the partitions to include

for each type of report found in segments 1 through 16.

Factory default is all partitions off for all segments. Table 10

describes the segment options:

Table 10: Location 4 options

Segment

Description

1

Alarms

2

Open/Close

3

Bypass

4

Zone Trouble

5

Power Trouble (AC failure or low battery)

6

Siren and telephone fault

7

Test reports

8

Program, download and log full

9

Tampers

10

Short circuit and ground fault

11

Sensor lost

12

Sensor low battery

13

Expander trouble

14

Failure to communicate

15

Zone activity monitor

16

Reserved for future use

Location 5, special events to report to email

– phone fault detected

This location has 8 segments and selects the partitions to

include when reporting special events to email. To exclude any

partition from reporting, turn off the LED corresponding to that

particular partition number. Enter the numbers of the partitions

to include for each type of report found in segments 1 through

4. Factory default is all partitions off for all segments.

Segments 5 to 8 are reserved for future use. Table 11

describes the segment options:

Table 11: Location 5 options

Segment

Description

1

Alarm restores

2

Telephone fault

3

Start download

4

Failure to communicate, data lost

Segment

Description

5 to 8

Reserved for future use

Location 6, events to report to pager

phone fault detected

Note:

Reporting must be enabled in the control panel for this

location to function.

This location has 16 segments and selects the partitions to

include when reporting to a pager. To exclude any partition

from reporting, turn off the LED corresponding to that particular

partition number. Enter the numbers of the partitions to include

for each type of report found in segments 1 through 16.

Factory default is all partitions off for all segments. Table 12

describes the segment options:

Table 12: Location 6 options

Segment

Description

1

Alarms

2

Open/Close

3

Bypass

4

Zone Trouble

5

Power Trouble (AC failure or low battery)

6

Siren and telephone fault

7

Test reports

8

Program, download and log full

9

Tampers

10

Short circuit and ground fault

11

Sensor lost

12

Sensor low battery

13

Expander trouble

14

Failure to communicate

15

Zone activity monitor

16

Reserved for future use

Location 7, special events to report to

pager

– phone fault detected

This location has 8 segments and selects the partitions to

include when reporting special events to a pager. To exclude

any partition from reporting, turn off the LED corresponding to

that particular partition number. Enter the numbers of the

partitions to include for each type of report found in segments 1

through 4. Factory default is all partitions off for all segments.