NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet

Table 6: Segment 1 options

Option Description

ON

OFF

1

Format

SIA

Contact ID

2

Test Signal

Daily

1

Weekly

2

3

Reserved for future use

4

Reserved for future use

5

Reserved for future use

6

Disable Cellular Service LEDs Disabled Enabled

7

Reserved for future use

8

Disable SIA DCS area modifier

3

Disabled Enabled

1

Daily test will be performed 24 hours (± 10 minutes) from time this

option is programmed.

2

Weekly test will be performed 168 hours (± 10 minutes) from time

this option is programmed.

3

Some older SIA DCS compatible receivers may not support the

use of area (partition) modifiers. In such cases, the area modifier must

be disabled (Option 8 on).

Segment 2 programs host acknowledgement requirements.

Factory default for all Segment 2 options is off. Table 7

describes the options:

Table 7: Segment 2 options

Option Description

ON

OFF

1

Central Station Messages Enabled Disabled

2

Email Messages

Enabled Disabled

3

Pager Messages

Enabled Disabled

4

Periodic test signals

Enabled Disabled

5 to 8

Reserved for future use

Segments 3 and 4 are reserved for future use.

Location 2, events to report to central

station

– phone fault detected

Note:

Reporting must be enabled in the control panel for this

location to function.

This location has 16 segments and selects the partitions to

include when reporting to the central station. To exclude any

partition from reporting, turn off the LED corresponding to that

particular partition number. Enter the numbers of the partitions

to include for each type of report found in segments 1 through

16. Factory default is all partitions on for segment 1; all

partitions off for segments 2 to 16. Table 8 describes the

segment options:

Table 8: Location 2 options

Segment

Description

1

Alarms

2

Open/Close

3

Bypass

4

Zone Trouble

5

Power Trouble (AC failure or low battery)

6

Siren and telephone fault

7

Test reports

8

Program, download and log full

9

Tampers

10

Short circuit and ground fault

11

Sensor lost

12

Sensor low battery

13

Expander trouble

14

Failure to communicate

15

Zone activity monitor

16

Reserved for future use

Location 3, special events to report to

central station

– phone fault detected

This location has 8 segments and selects the partitions to

include when reporting special events to the central station. To

exclude any partition from reporting, simply turn off the LED

corresponding to that particular partition number. Enter the

numbers of the partitions to include for each type of report

found in segments 1 through 4. Factory default is all partitions

off for segment 1 and 3; all partitions on for segments 2 and 4.

Segments 5 to 8 are reserved for future use. Table 9 describes

the segment options:

Table 9: Location 3 options

Segment

Description

1

Alarm restores

2

Telephone fault

3

Start download

4

Failure to communicate, data lost

5 to 8

Reserved for future use

Location 4, events to report to email

phone fault detected

Note:

Reporting must be enabled in the control panel for this

location to function.