Interlogix NX-591NE-GSM User Manual
Page 5
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
Table 6: Segment 1 options
Option Description
ON
OFF
1
Format
SIA
Contact ID
2
Test Signal
Daily
1
Weekly
2
3
Reserved for future use
4
Reserved for future use
5
Reserved for future use
6
Disable Cellular Service LEDs Disabled Enabled
7
Reserved for future use
8
Disable SIA DCS area modifier
3
Disabled Enabled
1
Daily test will be performed 24 hours (± 10 minutes) from time this
option is programmed.
2
Weekly test will be performed 168 hours (± 10 minutes) from time
this option is programmed.
3
Some older SIA DCS compatible receivers may not support the
use of area (partition) modifiers. In such cases, the area modifier must
be disabled (Option 8 on).
Segment 2 programs host acknowledgement requirements.
Factory default for all Segment 2 options is off. Table 7
describes the options:
Table 7: Segment 2 options
Option Description
ON
OFF
1
Central Station Messages Enabled Disabled
2
Email Messages
Enabled Disabled
3
Pager Messages
Enabled Disabled
4
Periodic test signals
Enabled Disabled
5 to 8
Reserved for future use
Segments 3 and 4 are reserved for future use.
Location 2, events to report to central
station
– phone fault detected
Note:
Reporting must be enabled in the control panel for this
location to function.
This location has 16 segments and selects the partitions to
include when reporting to the central station. To exclude any
partition from reporting, turn off the LED corresponding to that
particular partition number. Enter the numbers of the partitions
to include for each type of report found in segments 1 through
16. Factory default is all partitions on for segment 1; all
partitions off for segments 2 to 16. Table 8 describes the
segment options:
Table 8: Location 2 options
Segment
Description
1
Alarms
2
Open/Close
3
Bypass
4
Zone Trouble
5
Power Trouble (AC failure or low battery)
6
Siren and telephone fault
7
Test reports
8
Program, download and log full
9
Tampers
10
Short circuit and ground fault
11
Sensor lost
12
Sensor low battery
13
Expander trouble
14
Failure to communicate
15
Zone activity monitor
16
Reserved for future use
Location 3, special events to report to
central station
– phone fault detected
This location has 8 segments and selects the partitions to
include when reporting special events to the central station. To
exclude any partition from reporting, simply turn off the LED
corresponding to that particular partition number. Enter the
numbers of the partitions to include for each type of report
found in segments 1 through 4. Factory default is all partitions
off for segment 1 and 3; all partitions on for segments 2 and 4.
Segments 5 to 8 are reserved for future use. Table 9 describes
the segment options:
Table 9: Location 3 options
Segment
Description
1
Alarm restores
2
Telephone fault
3
Start download
4
Failure to communicate, data lost
5 to 8
Reserved for future use
Location 4, events to report to email
–
phone fault detected
Note:
Reporting must be enabled in the control panel for this
location to function.