Special features continued

The Far Outlet as a UPS

The Far Outlet 300S may be switched on and used to power devices even while its

charger cord is plugged in. This means it will function as a limited Uninterruptible Power
Supply (UPS). The Far Outlet's internal charger will “keep up” with the drain on the battery
as long as the devices being powered draw an average of 60 watts or less. Heavy loads
may be applied intermittently as long as the charger is then given enough time to recover
the battery charge.

Brownout/Transient Protection

The Far Outlet 300S has a very sophisticated charging circuit that will accept any

voltage from 85 to 265 VAC. Any supply voltage within this range will allow the charger to
function normally. This provides brownout and transient protection because the Far
Outlet's output remains at 115 volts AC regardless of fluctuations in the voltage supplied
to its charger. Think of the Far Outlet as your personal “Voltage Buffer” between the wall
outlet and your sensitive equipment.

As a Voltage Converter

The wide range of voltage (85 to 250 VAC, 50 to 60 Hz) that may be applied to the

Far Outlet's charger input also allows it to function as a voltage converter when traveling
in a foreign country. The Far Outlet will supply 115 VAC, 60 Hz even while being charged
using 250 VAC, 50 Hz. There is no need for any additional converters plus you have the
portability that only the Far Outlet can provide.