4 setting dip switch (only serial interface type), 4 setting dip switch, Only serial interface type) – CITIZEN CT-S281 User Manual
Page 19: Selecting baud rate
![background image](/manuals/67396/19/background.png)
— 16 —
3.4 Setting DIP Switch
(Only serial interface type)
DIP switch is provided only for serial interface specification.
The DIP switch is located at the bottom of the paper holder. To set the DIP
switch open the printer cover and remove the paper.
Baud Rate (bps)
Switch No.
Function
ON
OFF
FEED
FEED
ON
1
8
OFF
Baud rate selection
See Table below.
Initial
Settings
1
Communication condition DIP switch setting
Internal memory
ON
setting method
setting
2
Hand shake
XON/XOFF
DTR/DSR
OFF
3
Bit length
7 bits
8 bits
OFF
4
Parity check
With parity
None
OFF
5
Parity selection
Even parity
Odd parity
OFF
6
OFF
7
ON
8
Reserved
−
Fixed
OFF
Selecting baud rate
Switch No.
6
7
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
1200 bps and 38400 bps can also be selected by a command or the memory
switch. 9600bps is factory setting.