beautypg.com

Majestic fireplaces, Uvc / uvs vent-free heaters, Ember material placement – CFM UVC43 User Manual

Page 11: Lava rock, Flame adjustment, Flame characteristics, First firing

background image

11

Majestic Fireplaces

®

UVC / UVS Vent-Free Heaters

20000135

7. Place top left log (BE9 or BF11) onto locator notches.

Ensure log is secure.

8. Place top right log (BE10 or BF12) onto locator

notches. Ensure log is secure.

Ember Material Placement

Separate the ember material into small pieces and
place onto the burner in front of the front logs. Do NOT
pack down, leave in fluffy, loose condition for most re-
alistic ember effects. Do not install more embers on
the burner than come with the unit.
Application of excess loose material may adversely
affect performance of theheater.
Replacement loose embers must be purchased
through authorized Majestic Fireplaces dealers.

WARNING: All previously applied loose
material must be removed prior to reappli-
cation.

Lava Rock

The lava rock provided with this fireplace must be
placed on the firebox bottom on either side of the
burner assembly. Do not place lava rock in combustion
pan.

Under no circumstances should this lava
rock be placed on any part of the burner
assembly.

LG131

UVC/UVS36 LOGS

9/8/00 djt

BE10

BE8

BE7

BE6

BE9

LG131

Fig. 14 UVC/UVS36 log placement.

LG132

UVC/UVS43

Log placement

9/8/00 djt

BF11

BF8

BF9

BF10

BF12

LG132

Fig. 15 UVC/UVS43 log placement.

Flame Adjustment

For fireplaces equipped with HI/LO valves, flame ad-
justment is accomplished by rotating the HI/LO adjust-
ment knob located near the center of the gas control.
(Fig. 16)

LO

HI

Turn

counterclockwise

to decrease

flame height

Turn clockwise

to increase

flame height

HV102

Honeywell hi/lo knob

4/5/99 djt

Fig. 16 Flame adjustment knob for Honeywell Valve.

Flame Characteristics

It is important to periodically perform a visual check
of the pilot and burner flames. Compare them to the
Figures 17 or 18. If the flame patterns appear abnor-
mal, contact a qualified service provider for service and
adjustment.

Fig. 18 Approximate flame heights for each model.

UVC36/UVS43

UVC43/UVS43

LG131

UVC/UVS36 LOGS

9/8/00 djt

LG134

UVC/UVS43

Log placement flames

9/8/00 djt

LG133

LG134

IF449

NOVA SIT PILOT

UVC

2/14/97

FP449

Fig. 17 Correct pilot flame pattern.

First Firing

Upon completing the gas line connection, a small
amount of air will be in the lines. When first lighting unit
with pilot light, it will take a few minutes to purge them-
selves of this air. Once the purging is complete, the
pilot and burner will light and operate as indicated in the
instruction manual. Subsequent lightings of the heater
will not require such purging.
When lit for the first time, the appliance will emit a slight
odor for awhile. This is due to paint and lubricants used
in the manufacturing process. After each lighting, vapor
may condense and fog the glass; this moisture disap-
pears within a few minutes of burning.