beautypg.com

Label details – D.A.S. Audio Aero 40A User Manual

Page 11

background image

11

Manual del Usuario

/ aero

40A

/ User’s Manual

Label details

Zone for

user notes

SIGNAL

INPUT

CAUTION

DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

D.A.S. AUDIO S.A. (

MADE IN SPAIN

Valencia)

N1918

LOOP
THRU

ON

IDENTIFY
/COMMS

SIGNAL

/LIMIT

AMPLIF.

PROTECT

THROW

HIGH PASS FILTER

TO UNLOCK,

PRESS AND HOLD OK

FOR 2 SECONDS

NUMBER OF UNITS

IN

OUT

IDENTIFY

NUMBER OF UNITS

UNIT NAME

STAGE / VENUE

THROW

HIGH PASS FILTER

115/230 V~ 50/60Hz 620W

AC INPUT

MAX. 6@230V / 3@115V UNITS IN PARALLEL

AC OUTPUT

ID DASNET

02394

ON / OFF
A sound system should be switched on

sequentially. Switch on the self-powered units last
in your sound system (switch on the subwoofer
before the mid-high system). Switch on the sound
sources such as CD players or turntables, then the
mixer, then the processors, and finally the self-
powered unit. If you have several units, it is
recommended that you switch them on
sequentially one at a time.

Follow the inverse order when switching off,

turning self-powered units off before any other
element in the sound system.

Disconnect the device by removing the mains

connector from the mains socket. The mains
connector and mains socket must always be freely
accessible and never covered or blocked in any
way.

The models use a power cable equipped with

a Neutrik PowerCon TRUE1 connector. Power can
be daisy chained via the TRUE1 output connector
(see details on product label).

IMPORTANT: Do not disconnect the unit

while in use.

Ensure that the device is disconnected from

the mains by observing that the ON LED is turned
off. Please note that the ON LED can stay on for
several seconds after the mains power has been
disconnected.

Overheating

This equipment does not normally overheat

during normal conditions of use. When overheating
occurs, the unit protects itself. You should then
find out why and if necessary contact an
authorised dealer for technical assistance.

Equalisation
The unit does not need extreme settings of

equalisation to produce quality sound. Avoid high
levels of gain on the equalisers. Gain values above
+3 dB on a console’s EQ are not recommended.

Overload indicator

This device has a SIGNAL/LIMIT indicator. The

red light indicates the signal is excessive.

The indicator should not be lit continuously.

This distorts the signal (quickly fatiguing your ears)
and may damage the speakers.

Normally it is enough just to let the unit cool

down after you have corrected the problem so that
the system functions properly again.

The amplifier is provided with a radiator made

of aluminum which improves heat evacuation.

Keep grilles clean and dust-free.
Do not block or obstruct in any way the air

entrance or exit while the equipment is in use.

Air circulates from the bottom to the top of the

amplifier.

Low mains voltage

Therefore the current consumed by a 115V

version is double the 230V version to achieve the
same acoustic power level.

For 230Vac the consumption of the unit giving

1/3 of power (with pink noise input signal) is 3A.

If mains voltage falls below the shutdown

voltage for the unit, it will stop playing. When
acceptable levels are regained, the unit will switch
back on automatically.

The unit recognised automatically if it´s going to

work in 230Vac or 115Vac range

The nominal operating ranges are 90V to 125V

for 115Vac, or 180V to 250V for 230Vac..