Connections and operations, Cautions, Operation – Toshiba IK-628A User Manual
Page 5: Line - lock control
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

2. CONNECTIONS AND OPERATIONS
HPOWER CORD
(twisted pair line)
(*)Power cord: minimum wire size
of 18 AWG is recommended.
Line - Lock control
24V AC UL Listed Class 2 power supply
Do not overload power supply —
Since this camera uses 24V AC UL Listed
Class 2 power supply, it should be connected to
a power supply that allows for at least 5w
consumption.
Matching the vertical synchronization with the power frequency is called the Line-Lock.
When two or more cameras are switched by the video switcher for viewing by a monitor TV, the vertical
sync, phase can be locked with the power frequency, and a stable vertical sync, is obtained without
being disturbed at the time of switching.
MONITOR TV
CAMERA1
TO 24V AC UL Listed Class 2
power supply
Cautions;
• The camera is synchronized to the power frequency of 60 ± 1 Hz covering a normal fluctuation of the
power frequency. However, the camera may not cover a large fluctuation caused from the power
generated by an engine generator, etc.
• It takes about 10 seconds or more until a stable synchronization is obtained after the power is turned
on. This is normal, because several seconds are required to stabilize the camera against power
noise.
• Refer to '' 7.LINE-LOCK PHASE " for adjustment.
2. Operation
(1) Mount a lens on the camera and connect equipment. Applicable lenses are specified in Section 3
'■ LENS
(2) Adjust the lens diaphragm and focus for optimum image.