background image

13

T--326

S

YSTEM

M

AINTENANCE

3.1

M

AINTENANCE

S

CHEDULE

SYSTEM

OPERATION

ON OFF

OPERATION

a. Daily Maintenance

X

X

X

Pre--trip inspection -- after starting. (Refer to para-

graph 2.4)

Check tension and condition of drive belts.

b. Weekly Maintenance

X

X

Perform daily inspection

Check condenser, evaporator coils and return air

filters for cleanliness

c. Monthly Maintenance

X

X

X

X

X

X

Perform weekly inspection

Clean or replace Evaporator return air filters

Inspect Condenser coil fins -- Clean when neces-

sary

Inspect refrigerant hoses and fitting connections.

Inspect electrical harness and connections

Check battery voltage -- System operates efficiently

at 13.5 volts

d. Quarterly Inspection

X

X

X

X

X

X

Inspect Evaporator(s) coil fins (heater coil if

installed) Clean if needed.

Check blower operation.

Check current draw and voltage of system compo-

nents including fan motors.

Check that all compressor mounting brackets and

hardware are tight. Tighten and torque to proper

specifications.

Check hose and harness under vehicle for proper

support and protection

Check Evaporator drain lines.