ELECTRICAL PREPARATION
Electrical Preparation
Dishwasher Electrical Rating
Volts
Herti
Amperes
Watts
120
60
15
1,450
(max)
AWARNIN
__________ 1
To avoid e
energized
injury ord
perform el
on the dis:
are certair
de-energi
2
Electrical Shock Has
ilectrical shock, do not
circuit. Doing so coulc
ieath. Only qualified elc
Metrical work. Do not a1
hwasher electric suppi
1
the circuit is
:ed.
tard
work on an
i result in serious
sctricians should
Hempt any work
y circuit until you
AWARNIN
p 1
Fire Hazard
To avoid a fire hazard, make sure electrical work
is properly installed. Only qualified electricians
should perform electrical work.
Electrical Supply
The customer has the responsibility of ensuring that the
dishwasher electrical installation is in compliance with all
national and local electrical codes and ordinances. The
dishwasher is designed for an electrical supply of 120V,
60 Hz, AC, connected to a dishwasher-dedicated,
properly grounded electrical circuit with a fuse or breaker
rated for 15 amps. Electrical supply conductors shall be a
minimum #14 AWG copper wire rated at 75°C or higher.
Regardless of where the electrical supply cable enters the
enclosure, position the cable 21” {533mm) from the
enclosure’s left side, as shown in Figure 4. Extend the
cable 30” (762mm) from the enclosure’s back, as shown
in Figure 4.
Remove 3” - 4” (75mm -100mm) of the cable’s outer
casing, as shown in Figure 5, then remove 3/8” -1/2”
(9 -13mm) of insulation from each wire, as shown in
Figure 5.