ELECTRICAL PREPARATION

Electrical Preparation

Dishwasher Electrical Rating

Volts

Herti

Amperes

Watts

120

60

15

1,450

(max)

AWARNIN

__________ 1

To avoid e
energized

injury ord
perform el

on the dis:
are certair
de-energi

2

Electrical Shock Has

ilectrical shock, do not

circuit. Doing so coulc

ieath. Only qualified elc
Metrical work. Do not a1
hwasher electric suppi

1

the circuit is

:ed.

tard

work on an

i result in serious
sctricians should
Hempt any work

y circuit until you

AWARNIN

p 1

Fire Hazard

To avoid a fire hazard, make sure electrical work

is properly installed. Only qualified electricians

should perform electrical work.

Electrical Supply

The customer has the responsibility of ensuring that the
dishwasher electrical installation is in compliance with all
national and local electrical codes and ordinances. The
dishwasher is designed for an electrical supply of 120V,
60 Hz, AC, connected to a dishwasher-dedicated,
properly grounded electrical circuit with a fuse or breaker

rated for 15 amps. Electrical supply conductors shall be a

minimum #14 AWG copper wire rated at 75°C or higher.

Regardless of where the electrical supply cable enters the

enclosure, position the cable 21” {533mm) from the
enclosure’s left side, as shown in Figure 4. Extend the
cable 30” (762mm) from the enclosure’s back, as shown
in Figure 4.

Remove 3” - 4” (75mm -100mm) of the cable’s outer

casing, as shown in Figure 5, then remove 3/8” -1/2”
(9 -13mm) of insulation from each wire, as shown in

Figure 5.