A warning – Kenmore 505 User Manual
Page 21
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Flue Installation for the 305 and 505 Models
Horizontal Termination without using the Condensate Collector
A WARNING
If the condensate collector is not used, the drain pipe must
be capped to prevent exhaust gases and condensate from
entering the building. The cap is supplied on the appliance.
* The condensate collector must be used
in horizontal terminations if a vertical rise
in the vent system exceeds 5ft.
Maximum Height *
5 feet (1.52 m)
VI
r
^ ^
Regions of cold climate will create
more condensate in the vent system.
The condensate collector should be
used in cold climates.
If more than one elbow is used in the
vertical section the condensate
collector must be used.
Condensate Collector
Bracket
To adjust the condensate collector position or to
replace the female vent top with a male vent top:
1. Loosen the 4 screws at the rear bracket
2. Slide the bracket away from the female vent top.
3. Remove the 4 screws attaching the female vent
top to the water heater.
4. Lift up the female vent top and reposition as
desired (or replace with a male vent top).
5. Install the 4 screws at the vent top and tighten the
4 screws at the bracket.
11
Securing Screw
Secure the first vent component to the water heater
with one self-tapping screw at the hole located above
the condensate collector.
Figure 10
305 & 505 Indoor Manual
21