Venting products – Kenmore 505 User Manual
Page 19
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
VENTING PRODUCTS
Table 5: Listed and Tested Vent Products for the 305 and 505 Models
Manufacturer
Product
Parts
Ubbink
Rolux Vent System
Refer to the manufacturer’s technical literature for specific part numbers and
instructions.
Heat-Fab
Saf-T Vent SC system
Metal-Fab
Corr/Guard Vent/Air Intake System
Vent Manufacturer Contact
Information for Installation Instructions and Parts Lists:
Ubbink
Heat-Fab
Metal-Fab Inc.
Telephone: 866-677-4960
Telephone: 800-772-0739
Telephone: 800-835-2830
500 Tennessee Waltz Parkway
Fax: 413-863-4803
316-943-2351
Ashland City, TN 37015
Fax: 316-943-2717
E-mail: [email protected]
Figure 8: Flue Terminal Clearances (ANSI Z21.10.3 • CSA 4.0)
Ref
Description
US Installations
A
Clearance above grade, veranda, porch, deck, or balcony
12 inches (30 cm)
B
Clearance to window or door that may be opened
12 inches (30 cm)
C
Clearance to permanently closed window
*
D
Vertical clearance to yentilated soffit, located aboye the terminal within a
horizontal distance of 2 feet (61 cm) from the center line of the terminal
*
E
Clearance to unyentilated soffit
*
F
Clearance to outside corner
*
G
Clearance to inside corner
*
H
Clearance to each side of center line extended aboye meter/regulator
assembly
*
I
Clearance to seryice regulator yent outlet
*
J
Clearance to nonmechanical air supply inlet to building or the combustion air
inlet to any other appliance
12 inches (30 cm)
K
Clearance to a mechanical air supply inlet
3 feet (91 cm) aboye if within
10 feet (3 m) horizontally
L
Clearance aboye payed sidewalk or payed driyeway located on public property
*
M
Clearance under yeranda, porch, deck, or balcony
*
© A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves
both dwellings.
© Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the
requirements of the gas supplier.
305 & 505 Indoor Manual