Figure 5: Recommended Piping for Circulation Systems

^____ I

°o

n

o'^

I_____

f

o

NOTE:

Applications, using this piping
arrangement maintains fuli
warranty.

For this application:

Pump should be controlled by an Aqua-

stat, Timer or Combination Aquastat and
Timer.

Pump to be sized to maintain circulation
loop temperature.

The pump should be sized to overcome
the pressure loss through the tank water

heater, and supply and return plumbing.

Pump to be of bronze or stainless
construction.

Water Heater

Equipment List

QTY

Water Heaters

Plumbing Installation

Kit

(Optional)

(

3

/

4

"

Fittings Include:

2 Unions, 2 Ball Valves,
2 Drain Valves and

1 Pressure Relief Valve

3/4" Gas Connection

L

q

-p Gas Supply

L

q

o

o

+

Minimum 3/4" Cold Water Sup^ Line

-M!—

^-\ÒÌ-

IMPORTANT: Connect the building
return line to the hot water supply line

as close as possible to the water

heater.

Tank Water Heater to be Sized for

Heat Loss of Circulation Loop.

Building Supply

Electric Water

Heater

7T

Building

Fixtures

Expansion Tank

KEY

3/4" Ball Valve

s

Pressure Regulator

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

eft

Solenoid Valve

This is not an engineered drawing. It is intended only as a guide and not
as a replacement for professionally engineered project drawings. This
drawing is not intended to describe a complete system. It is up to the
contractor/engineer to determine the necessary components and
configuration of the particular system being installed. This drawing does
not imply compliance with local building code requirements. It is the

responsibility of the contractor/engineer to ensure installation is in
accordance with all local building codes. Confer with local building
officials before installation.

16