TABLE 1—MODEL SPECIFICATIONS
MODEL AND DESCRIPTION
SYSTEM
SWITCHING
(dpst and dp3t)
FAN
SWITCHING
(spdt)
SUBBASE TERMINALS
WIRING
DIAGRAM
R
W
Y
B
G
o
X
p
z
Rc
R»
Q539A Subbases provide system
and fan switching and cooiing
anticipation to controi heating and
cooiing appiications.
Q539A1014, Q539A4026' for
single heating and cooling
transformer applications.
COOL-OFF-HEAT
ON-AUTO
X
X
X
X
X
X
Fig. 1
Fig. 2
Q539A1022 with impedance
relay reset switch.
COOL-OFF-
HEAT-RESET
ON-AUTO
X
X
X
X
X
X
Fig.1
Fig. 2
Q539A1022 with indicator LED
for impedance relay reset
switch.
COOL-OFF-
RESET-HEAT
ON-AUTO
X
X
X
X
X
X
X
Fig. 1
Fig. 2
Q539A1022 with impedance
relay reset switch for heat
pump applications.
COOL-OFF-
RESET-HEAT
ON-AUTO
X
X
X
X
X
X
Fig. 3
Q539A1121 with special
resistor for gas air conditioning
applications.
COOL-OFF-HEAT
ON-AUTO
X
X
X
X*
X
X
Fig. 1
Fig. 2
Q539A1147, Q539A4000‘ for
applications with isolated heating
and cooling circuits.
COOL-OFF-HEAT
ON-AUTO
X
X
X
X
X
Fig. 4
Fig. 5
Q539A1162 used with W884
Comfort Control Center only.
COOL-OFF-HEAT
ON-AUTO
X
X
X
X
X
X
Fig. 1
Fig. 2
Q539A1196 with “G” terminal
isolated on heating for external
low voltage fan switch.
COOL-OFF-HEAT
ON-AUTO
X
X
X
X
Fig. 6
Q539A1394 with indicator LED
for oil burner applications"
COOL-OFF-HEAT
ON-AUTO
X
X
X
X
X
Fig. 7
Q539B1005 with system
switching and cooling
anticipation for heating and
cooling applications. No fan
switching.
COOL-OFF-HEAT
NONE
X
X
X
X
X
Fig. 1
Fig. 2
Q539C1020, Q539C4008’' with
system and fan switching and
cooling anticipation for cooling-
only applications.
COOL-OFF
ON-AUTO
X
X
X
X
Fig. 8
Q539G1000 with system and fan
switching for control of heating-
only system. No cooling
anticipator. Summer fan operation
available.
HEAT-OFF
ON-AUTO
X
X
X
X
x“
Fig. 9
Q539H1009 with fan switching,
cooling anticipation, and "Z”
terminal for remote AUTO FAN
switching. No system switching.
NONE
ON-AUTO
X
X
X
X
X
Fig. 10
Q539J1006, Q539J400(y= with
system switching and cooling
antidpation for electric heat and
heat pump applications. Fan
relay controls AUTO FAN
operation.
COOL-OFF-HEAT
ON-AUTO
X
X
X
X
X
X
X
Fig. 11
(continued on next page)