A CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the
water heater must be accomplished in such a manner that if
the tank or any connections should leak, the flow of water will
not cause damage to the structure. When such locations can­
not be avoided, a suitaNe drain pan should be installed under
the water heater. Drain pans are available at your local Sears
store. Such a drain pan must be not greater than I

'/%

inches

deep, have a minimum length and width of at least 2 inches
greater than the water heater dimensions and must be piped
to an adequate drain. Tîie pan must not restrict combustion air
flow. Under no circumstances is the manufacturer or Sears to
be held liable for any water damage in connection with this

water heater.

AWARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES,

STORAGE,

AND

UTILITY

AREAS,

ETC):

Flammable liquids (such as gasoline, solvents, propane (LP) or
butane, etc.), all of which emit flammable vapors, may be
improperly stored or used in such areas. The gas water heater
pilot light or main burner can ignite such vapors. The resulting

flashback and fire can cause death or serious bums to anyone in
the area, as ¥№ll as property dam^.

if installation in such areas is your only option, then the installa­

tion must be accomplished in a way that the pilot flame and

main burner flame are elevated from the floor at least 18 inches.

White this msqf reduce the chances of flammable vapors from a
floor spill being ignited, gasoline and other flammable substances
should never stored or used in the same room or area con­
taining a gas water heater or other open flame or spark produc­
ing appliance.

NOTE: Flammable vapors may be drawn by air currents from

other areas of the structure to the appliance.

AWARNING

Propellants of aerosol sprays and volatile compounds, (clean­

ers, chlorine based chemicals, refrigerants, etc.) in addition to
being highly flammable in many cases, will also change to cor­
rosive hydrochloric acid when exposed to the combustion
products of the water heater. The results can be hazardous,
and also cause product fejiure.

The location selection must provide adequate clearances for ser­

vicing and proper operation of the water neater.

Facts to Consider About the
Location

You should carefully choose an indoor location for the new

water heater, because the placement is a very important consid­

eration for the safety of the occupants in the building and for

the most economical use of the appliance. This water heater is

not for use in mobile homes or outdoor installation.

Whether replacing an old water heater or putting the water

heater in a new location, the following critical points must be

observed.

• The location selected should be indoors as close as‘practical

to the gas vent or chimney to which the water heater vent is

going to be connected, and as centralized with the water pip­

ing system as possible. The water heater, as all water heaters,

will eventually leak. Do not install without adequate

drainage provisions where water flow will cause damage.

Installation Instructions (cont’d)

AWARNING

This water heater must not be installed directly on carpeting.
Carpeting must be protected by a metal or wood panel
beneath the appliance extending beyond the full width and
depth of the appliance by at least 3 inches (76.2mm) in any
direction, or if tlie appliance is installed in an alcove or closet,
the entire floor must be covered by the panel. Failure to heed
this warning may result in a Are haz^.

AWARNING

Minimum clearances between the water heater and com­
bustible or non-combustible construction are I" at the sides
and rear, 4" at the front, and 6" from the vent pipe. Clearance
from the top of the jacket is 18" on most models. Note that a
lesser dimension may be allowed on some models. Refer to the
labd on the water heater adjacent to the gas control valve for
all clearances.

12" MAX.

1100««, in i

I rwnwwiB I

VENTILATiON

AIK

OPENINGS

in.l

ininwm I __________

I'MIN

TOP VIEW

OF CLOSET

WITHOUT DOOR

Il'MIN.

4‘ MIN.

12‘ MAX.

TOP VIEW

OF CLOSET

WITH Dc30R

r MIN.

I

RECTANGULAR

I

3"

AIR DUCT

I

MIN.

Figure I

AIR DUCT

AWARNING

A gas water heater cannot operate properly without the cor­

rect amount of air for combustion. Do not install in a confined

area such a closet, unless you provide air as shown in the “Facts
to Consider About the Location" section. Never obstruct the
flow of ventilation air. If you have any doubts or questions at all,
call your gas company. Failure to provide the proper amount of
combustion air can result in a fire or explosion and can cause

DEATH, SERIOUS BODILY INJURY; OR PROPERTY DAMAGE.

AWARNING

If titis water heater will be used in beauty shops, bari)er shops,

cleaning establishments, or self-service laundries with dry
cleaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation
air be taken from outside these areas. Refer to the “Facts to

Consider About the Location" section of this manual and also

the latest edition of the National Fuel Gas Code, ANSI Z223.I,
also referred to as NFPA 54 for specifics provided concerning
air required.