Customer responsibilities, Product specifications – Kenmore 153.33459 User Manual
Page 6
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Customer Responsibilities
Thank You
for purchasing a Sears water heater.
Properly installed and maintained, it ^ould give you years of
trouble free service. If you should decide that you want the new
water heater professionally installed by Sears call the local Sears
Service Center or any Sears store. They will arrange for prompt,
quality installation by Sears authorized contractors.
Abbreviations Found In This Instruction Manual
A.G.A. - American Gas Association
A.N.S.I. - American National Standards Institute
AWARNING
This gas-fired water heater is design certified by the
American
Gas
Association
Laboratories
under
American
National Standards for Gas Water Heaters. The installa
tion must conform with this manual, Local Codes and with
the latest edition of the National Fuel Gas Code, ANSI
Z223.I.
This pubiication is available fn>m your local government or
public
library,
gas
company,
or
by
writing
NFPA,
Batterymarch P^k, Quincy, MA 02269.
Read the “Safety Precautions” section, pages 2 through 4 of
this manual first and then the entire manual carefully. If you
don’t follow the safety rules, the water heater will not operate
properly. It could cause DEATH, SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE.
This manual contains instruaions for the installation, opera
tion, and maintenance of the gas-fired water heater. It also
contains warnings through out the manual that you must read
and be aware of All warnings and all instructions arc essential
to the proper operation of the water heater and your safety.
Since we cannot put everything on the first few pages,
READ
THE ENTIRE MANUAL BEFORE ATTEMPTING TO
INSTALL OR OPERATE THE 'WATER HEATER.
The installation must conform with the instructions in this
manual; gas company rules; and Local Codes, or in the
absence of Local Codes, with the latest edition of the National
Fuel Gas code, ANSI Z223.1, also referred to as NFPA 54.
This publication is available from your local government or
public library or gas company or by writing NFPA,
Batterymarch Park, Quincy, MA 02269.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears
Service Center.
Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe instal
lation are very important in preventing death from possible
carbon monoxide poisoning and fires.
Examine the location to ensure the water heater complies with
the “Facts to Consider About the Location” section in this
manual.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation proce
dures. Instructions may be obtained from your local dealer,
wholesaler, public utilities or California Office of the State
Architect, 400 P Street, Sacramento, CA 95814.
Product Specifications
MODEL
NUMBER
TANK
CAPACITY
IN GALLONS
TYPE
OF
GAS
B.T.U.
RATE
RECOVERY RATE
GALS. PER HOUR
@ 90“F RISE
MINIMUM
VENT
PIPE
DIMENSIONS IN INCHES
DIAMETER
HEIGHT TO
JACKET TOP
153.33429040
NATURAL
35,000
35.8
3" - 4"
20
ATh
153.33439030
NATURAL
28,000
28.7
3"
16
56
153.33449040
NATURAL
30,000
31.0
3"
18
5614
153.33459050
NATURAL
30,000
31.0
3"
20
%Vi