Awarning, Sediment trap, Gas piping with flexible connector – Kenmore 153.33459 User Manual
Page 15: Gas piping with all black iron pipe to gas control, Installation instructions (contad)
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Installation Instructions (contad)
AWARNING
• The appliance and its individual shutofT valve must be discon
nected from the gas supply piping system during any pressure
testing of the gas system at test pressures in excess of
'A
pound per square inch (3.5kPa),
• The appliance must be isolated from the gas supply piping sys
tem 1^ closing its individual manual shutoff valrc during any
pressure testing of the gas supply piping system at test pres
sures equal or less than
'A
pound ^r square inch (3.5kPa).
AWARNING
Use pipe joint compound or teflon tape marked as being
resistant to the action of petroleum [Propane (LP.)] gases.
SEDIMENT TRAP
A sediment trap shall be installed as close to the inlet of the
water heater as practical at the time of water heater installation.
The sediment trap shall be either a tee fitting with a capped nip
ple in the bottom outlet or other device recognized as an effec
tive sediment trap. If a tee fitting is used, it shall be installed in
conformance with one of the methods of installation shown
below.
Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods shown.
AWARNING
Contaminants in the gas lines may cause improper operation
of the gas control valve that may result in fire or explosion.
Before attaching the gas line be sure that all gas pipe is clean
on the inside, lb trap any dirt or foreign material in the gas
supply line, a drip leg (sometimes called a sediment trap)
must be incorporated in the piping. The drip leg must be
readily accessible. Install in accordance with the “Gas Piping”
section. Refer to the latest edition of the National Fuel Gas
Code, ANSI Z223.I, also referred to as NFPA 54.
GAS PIPING WITH
FLEXIBLE CONNECTOR
FLEXIBLE GAS CONNECTOR
LABELED AS COMPLYING
Wrm ANSI STANDING
GROUND JOINT
UNJON{Optional)
-bcAP
GAS PIPING WITH ALL BLACK IRON
PIPE TO GAS CONTROL
GAS
¡CONTROL
VALVE
15