Awarning, Safety precautions – Kenmore 153.33459 User Manual
Page 3
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Safety Precautions
AWARNING
AWARNING
A gas water heater cannot operate properly without the
correct amount of air for combustion. Do not install in a
confined area such a closet, unless you provide air as
shown in the “Facts to Consider About the Location” sec
tion. Never obstruct the flow of ventilation air. If you have
any doubts or questions at all, call your gas company.
Failure to provide the proper amount of combustion air
can result in a fire or explosion and can cause DEATH,
SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
This water heater must not be installed directly on car
peting. Carpeting must be protected by a metal or wood
panel beneath the appliance extending beyond the full
width and depth of the appliance by at least 3 inches
(76.2mm) in any direction, or if the appliance is installed
in an alcove or closet, the entire floor must be covered by
the panel. Failure to heed this warning may result in a
fire hazard.
AWARNING
HOTTER
WATER
CAN
SCALD:
Water
heaters
are
intended to produce hot water. Water heated to a tem
perature which will satisfy clothes washing, dish washing,
and other sanitizing needs can scald and permanently
injure you upon contact. Some people are more likely to
be permanently injured by hot water than others. These
include the elderly, children, the infirm, or physically/men-
tally handicapped. If anyone using hot water in your home
fits into one of these groups or if there is a local code or
state law requiring a certain temperature water at the hot
water tap, then you must take special precautions. In addi
tion to using the lowest possible temperature setting that
satisfies your hot water needs, a means such as a mixing
valve, should be used at the hot water taps used by these
people or at the water heater. Mixing valves are available
at plumbing supply or hardware stores. Follow manufac
turers instructions for installation of the valves. Before
changing the factory setting on the thermostat, read the
“Temperature Regulation” section in this manual.
AWARNING
Soot build-up indicates a problem that requires correc
tion before further use. Turn “OFF” gas to water heater
and leave “OFF” until repairs are made, because failure
to correct the cause of the sooting can result in a fire or
explosion
causing DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.
AWARNING
VENT DAMPERS - Any vent damper, whether it is operat
ed thermally or otherwise must be removed if its use
inhibits proper drafting of the water heater. .
Thermally
Operated
Vent
Dampers;
Gas-fired
water
heaters having thermal efficiency in excess of 80% may
produce a relatively low flue gas temperature. Such tem
peratures may not be high enough to properly open ther
mally operated vent dampers. This would cause spillage of
flue gases and may cause carbon monoxide poisoning.
Vent dampers must bear evidence of certification as com
plying
with
the
latest
edition
of
American
National
Standard ANSI Z2I.68 (ANSI Z2I.66 & 67, respectively,
cover
electrically
and
mechanically
actuated
vent
dampers). Before installation of any vent damper, consult
your local Sears Service Center or the gas utility for fur
ther information.
AWARNING
*The appliance and its individual shutoff valve must be dis
connected from the gas supply piping system during any
pressure testing of the gas system at test pressures in
excess of
'A
pound per square inch (3.5kPa).
• The appliance must be isolated from the gas supply pip
ing system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping sys
tem at test pressures equal or less than '/i pound per
square inch (3.5kPa).
AWARNING
BEFORE
LIGHTING
[PROPANE
(L.P.)
GAS
WATER
HEATERS]: Propane (LP.) gas is heavier than air. Should
there be a leak in the system, the gas will settle near the
ground. Basements, crawl spaces, skirted areas under
mobile homes (even when ventilated), closets and areas
below ground level will serve as pockets for the accumula
tion of this gas. Before attempting to light or relight the
water heatePs pilot or turning on a nearby electrical light
switch, be absolutely sure there is no accumulated gas in
the area. Search for odor of gas by sniffing at ground level
in the vicinity of the appliance. If odor is detected, follow
steps indicated at “For Your Safety” on the cover page of
this manual then leave the premises.
AWARNING
Chemical vapor corrosion of the flue and vent system
may occur if air for combustion contains certain chemical
vapors. Spray can propellants, cleaning solvents, refngera-
tor
and
air
conditioner
refrigerants,
swimming
pool
chemicals, calcium and sodium chloride, waxes, bleach,
and process chemicals are typical compounds which are
potentially corrosive.
AWARNING
Obstructed or deteriorated vent systems may present a
serious health risk or asphyxiation.
Safety Precautions continued on page 4