PILOT LIGHT TROUBLESHOOTING FLOWCHART
Section A: Pilot light will not light (new installation).
Is the manual gas shut-off valve,
located in the supply line to the
water heater, in the on position?
Turn the manual gas shut-off valve to
■ NO the on position and follow the lighting
instructions on the front of the water heater.
YES
I
Have you bled all the air
from the pilot tube and
gas supply line?
■ NO^
YES
I
While repeatedly depressing the igniter
button, push in and hold the gas control/
temperature knob until the pilot is lit and
maintains a stable flame (status light will
blink). It may take up to 90 seconds of
pilot operation before status light blinks.
Once status light blinks, release the gas
control/temperature knob.
Is the igniter producing a
spark?
■YES
NO
Follow the “Testing the Igniter
System” section in this manual.
Set thermostat to desired temperature.
Section B: Pilot light repeatedly goes out.
Check the Base-Ring Filter and
Flame Arrestor for blockage due
to lint or dust. Are both the Air
Filter and Flame Arrestor clean?
■ NO^
Refer to the “Maintenance of
your Water Heater” section of this
manual for information on cleaning
the flame arrestor and burner.
YES
Does the flame
arrestor show signs
of discoloration?
NOi
Reassemble the heater, press the thermal
switch, and attempt to return the heater to
service. Does the pilot remain lit?
YES
Shut-off the gas supply to the water heater at the
manual gas shut-off valve, and contact Sears Service
at 1-800-MY-HOME (1-800-469-4663).
YES
NO
Set to desired temperature.
Does the diagnostic status light on the
gas control valve/thermostat give
a two flash error code?
YES
NO
Go to section C.
Refer to the “Replacing the Pilot
Assembly” instructions in the manual.
Reassemble and restore to service.
Section C: Pilot light will not remain lit.
Complete this section after completing Section B.
Check for insufficient combustion air.
YES
^___________________________
Are the combustion air supply and ventilation openings
of sufficient size? See “Combustion Air Supply and
Ventilation” section in this manual for requirements.
■ NO^
Correct size of
openings to allow
sufficient air.
YES
Does the return air duct for the furnace/
air handler/air conditioner draw its air from
the same location as the water heater?
See the “Location Requirements” section
and the “Combustion Air Supply” section.
NOJ
Is there proper
drafting at the
drafthood? See
“Checking the Draft”
section in this manual.
iNOi
YES
YES
Contact a Heating and Air
Conditioning service technician
to relocate the return air duct.
The water heater’s pilot can be
extinguished when the heating
or cooling system is turned on
if the return air duct is in the
same location.
Check the vent system for
restrictions/obstructions and
check the vent termination
height. Refer to the “Installation
Instructions” section of this
manual for specific requirements.]
If you are still having difficulty keeping the pilot
lit.
Contact
Sears
at
1-800-4-MY-HCME
(1-800-469-4663) to request service.
NOTE: If you are still experiencing difficulties
after following the steps in sections A, B, and C,
please contact Sears Service at 1-800-MY-HOME
(1-800-469-4663).
THERMAL SWITCH LOCATION
FIGURE 45.
41