For your safety read before lighting, Lighting instructions – Kenmore 153.33114 User Manual
Page 24
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
FOR YOUR SAFETY READ BEFORE LIGHTING
BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED
A. This appliance has a pilot which is lit by a piezo- •
electric spark gas ignition system. Do not open
the inner door of the appliance and tryTo light
the pilot by hand.
C
B.
BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
q
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
WITH WATER AND AIR PURGED FROM ALL LINES
If you cannot reach your gas supplier, call the fire
department.
Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
Do not use this appliance if any part has been under
water. Immediately contact a qualified installer or
service agency to replace a flooded water heater.
Do not attempt to repair the unit! It must be replaced!
LIGHTING INSTRUCTIONS
Gas Control/Temperature Knob
■Igniter
GAS CONTROL
' PILOT
"OFF" POSITION
¥*C pitoT
"PILOT" POSITION
■CONTROL KNOB
’ PILOT
"ON" POSITION
MAIN BURNER
^PILOT
FIGURE 'D'
STOP! It is imperative that you read all
warnings before lighting the pilot.
safety
©
Follow “ B” in the safety
on this label. If you do not
Turn the gas control/temperature knob
counterclockwise t)to the "OFF" setting.
Wait ten (10) minutes to clear out any gas. If you then
smell gas, STOP!
information above\g#on this label,
smell gas, go to the next step.
Turn the gas control/temperature knob clockwise Gto “
PILOT”. See Figure ‘B’.
Press the gas control/temperature knob all the way
in and hold it in. The knob should travel in about
1/4 inch (6.35 mm) if it is set to "PILOT" correctly.
While holding the aas control/temperature knob in.
click the igniter button continuously (about once a
second) for
UP
to 90 seconds or until Status Light
begins to blink.
When the status light starts blinking, release the
gas control/temperature knob. Set the gas control/
temperature knob to the desired setting. See Figure ‘O’.
If the status light does not start blinking within 90
seconds, repeat steps 2 through 5 up to THREE
(3) times, waiting 10 minutes between lighting
attempts.
The circuitry in this advanced aas valve requires
that you wait 10 minutes between lighting attempts.
If the status light turns solid red, release the gas
control/temperature knob and repeat steps 2 through
5 (waiting 10 minutes before attempting to relight the
pilot).
If the status light does not start blinking after three
lighting attempts, turn the gas control/temperature knob
to "OFF" and call a qualified service technician or your
gas supplier.
iBiffiMSHIpHotter water increases the risk of scald
injury. Consult the instruction manual before
changing temperature.
Refer to the Lighting Instructions in the Installation
Manual for more detailed troubleshooting
information.
TO TURN OFF GAS TO APPLIANCE
1. Turn the gas control/temperature knob counterclockwisePto the "OFF" setting. The status light will stop blinking and stay
on for a short time after the water heater is turned off. See Figure ‘A’.
24