beautypg.com

Installation instructions (cont’d), Installation checklist – Kenmore 153.31614 User Manual

Page 15

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Installation Instructions (cont’d)

Installation Checklist

Whether or not the element conversion is made, the model

rating plate must be marked. Using a hard point ink pen,

check the appropriate block within the model rating place,
which is located adjacent to the lower access panel.

Is the fuse or circuit breaker size correct as shown in the chart

in the “Product Specifications” section?

Are the wires from the circuit breaker or fuse service to the

water heater's junction box on the correct wire size (gauge) as
shown in the chart in the “Product Specifications” section?

Is the new temperature-pressure relief valve properly installed,
and piped to an adequate drain? See “Temperature-Pressure
Relief Valve” section.

Is the water heater completely filled with water? See “Filling
the

Water

Heater”

instructions

in

the

“Installation

Instructions” section.

Will a water leak damage anything? See “Facts to Consider
About the Location” section.

Are the cold and hot water lines connected to the water heater

correctly? See “Water Piping” instructions in the “Installation
Instructions” section.

Is there adequate clearance for maintenance around the water

heater?

Do you need to call your electric company to check your
wiring?

15

This manual is related to the following products: