SERVICE TECH. INFORMATION

A. TROUBLESHOOTING

CORRECT

SWITCH

DISPLAYS

VALVE CYCLE STATUS

Valve in service, fill, brining,

backwash or fast rinse position

- P

Valve rotating from one position
to another

While in this diagnostic screen, the following in­

formation is available and may be beneficial for

various reasons. This information is retained by

the computer from the first time electrical power
is appHed to the face plate.

- - Press Q to display the number of days this

face plate has had electrical power applied.

-- Press 0 to display the number of regenera­

tions initiated by this face plate since the SR code
number was entered.

Press and hold the SELECT button until...

SR 22

shows.

UltraSoft 100

SR 24

shows.

UltraSoft 150

CODE

CODE

5RE4

This code identifies the softener nominal capacity

size. If the wrong number shows, the softener will

operate on incorrect programming. Do the follow­
ing as needed.

Return the present time display
LECT button.

Press the SE-

To change SR number — Press the UP or DOWN

button until the correct SR code shows. Then, press

the SELECT button and reset the timer. ..page 1-3.

TIMER PWA REPLACEMENT: Be sure the
valve is in service position when replacing the

timer PWA (observe valve cycle indicator).

If, after installing and programming the re­
placement timer PWA, the valve is not in ser­
vice position, do the following to assure correct
cycle orientation, or timing, between the face­
plate and valve.

Use the MANUAL ADVANCE procedures,
page 5-4. With the RECHARGE NOW button,
advance through the recharge cycles until the
valve stops in service position, and RE­
CHARGE no longer flashes in the display.

NOTE: The valve motor may automatically
drive through several valve positions while
searching for service. If an error code occurs,
unplug the transformer, then plug in again.

ino

position
markers

(valve in

service)

CAM

5 - 3

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line